Current Transducer HXS 10-NP/SP3
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 10, 20 A
DUAL PHASE
All Data are given with a RL = 10 kΩ
Electrical data
IPN
IPM
VOUT
GTH
VREF
RL
ROUT
CL
V C
IC
Primary nominal current rms
Primary current, measuring range
Analog Output voltage @ IP
Theoretical sensitivity
Reference voltage 1) Ouput voltage
Ouput impedance
Load impedance
Load resistance
Output internal resistance
Capacitive loading (± 20 %)
Supply voltage (± 5 %) 2)
Current consumption @ VC = 5V
Serial Parallel
± 10 ± 20
A
Serial Parallel
± 30 ± 60
A
VOE ± (0.625. IP/ IPN) V
0.625
V/ IPN
2.5 ± 0.025
V
typ. 200
Ω
≥ 200
kΩ
≥ 2
kΩ
< 5
Ω
= 4.7
nF
5
V
19
mA
Accuracy - Dynamic performance data
X
Accuracy 3) @ IPN , TA = 25°C
εL
Linearity error
0 .. IPN
0 .. 3 x IPN
TCVOE Temperature coefficient of VOE (+25.. 85°C)
(-40.. +25°C)
TCVREF Temperature coefficient of VREF (+25.. 85°C)
(-40.. +25°C)
TCVOE/VREFTemperature coefficient of VOE /VREF
TCG
Temperature coefficient of G
VOE
Electrical offset voltage @ IP = 0, TA = 25°C
VOM
Magnetic offset voltage @ IP = 0
after an overload of 3 x IPN
tra
Reaction time to 10 % of IPN step
tr
Response time to 90 % of IPN step
di/dt
di/dt accurately followed
Vno
Output voltage noise (DC .. 10 kHz)
(DC .. 1 MHz)
BW
Frequency bandwidth (- 3 dB) 4)
≤ ± 1
%
≤ ± 0.5
%
≤ ± 1
%
≤ ± 0.4
mV/K
≤ ± 0.525
mV/K
≤ ± 0.01
%/K
≤ ± 0.015
%/K
≤ ± 0.15
mV/K
≤ ±0.05 % of reading/K
VREF ± 0.0125
V
± 0.7
< 3
< 5
> 50
< 20
< 40
DC .. 50
%
µs
µs
A/µs
mVpp
mVpp
kHz
General data
TA
Ambient operating temperature
- 40 .. + 85
°C
TS
Ambient storage temperature
- 40 .. + 85
°C
m
Mass
10
g
Standards
EN 50178: 1997
Notes: 1) It is possible to overdrive VREF with an external reference voltage between
1.5 - 2.8 V providing its ability to sink or source approximately 5 mA.
2)
Maximum supply voltage (not operating) < 6.5V
3)
Excluding Offset and Magnetic offset voltage.
4) Small signal only to avoid excessive heatings of the magnetic core
120416/14
Features
●● Hall effect measuring principle
●● Multirange current transducer
through PCB pattern lay-out
●● Galvanic isolation between
primary and secondary circuit
●● Isolation test voltage 3500 V
between Primary and Secondary
●● Low power consumption
●● Extremely low profile < 11 mm
●● Single power supply + 5 V
●● Fixed offset & sensitivity
●● Isolated plastic case recognized
according to UL 94-V0.
Special feature
●● Two separate primary windings
for dual phase measurement.
Advantages
●● Small size and space saving
●● Only one design for wide current
ratings range
●● High immunity to external
interference
●● Internal & external reference.
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application domain
●● Industrial.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3
www.lem.com
Current Transducer HXS 10-NP/SP3
Isolation characteristics
Vd
dCp
dCI
CTI
Rms voltage for AC isolation test, 50 Hz, 1 min
Primary to secondary
Primary 1 to primary 2
Creepage distance
Clearance distance
Comparative Tracking Index (group I)
3.5
2.5
> 5.5
> 5.5
> 600
kV
kV
mm
mm
V
Applications examples
According to EN 50178, IEC 61010-1 standards and following conditions:
●● Over voltage category OV 3
●● Pollution degree PD2
●● Non-uniform field
EN 50178
IEC 61010-1
Single isolation
600 V
600 V
Reinforced isolation
300 V
150 V
According to UL508 standard and following conditions: Max. Voltage 600V
●● Over voltage category OV 3
●● Pollution degree PD2
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
120416/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HXS 10-NP/SP3 (in mm)
Required connection circuit
5V
HXS 10-NP
/SP3
47nF
4.7nF
47nF
Primary
connections
Serial
Parallel
Primary current
nominal
IPN [ A ]
maximum
IP [ A ]
10
30
20
Primary
resistance
RP [ mW ]
Primary insertion
inductance
LP [ µH ]
0.2
0.1
60
0.05
Mechanical characteristics
●● General tolerance
●● Transducer fastening &
connection of primary jumper
●● Transducer fastening &
connection of secondary
0V
Output
V Ref. IN/OUT
Recommended
PCB connections
IN
1
7
IN
2
1
8
7
OUT
2
8
OUT
0.025
Recommended PCB hole
± 0.2 mm
4 pins □ 1.2 mm
(corner R 0.4mm)
4 pins 0.5 x 0.25 mm
●● Primary PCB hole
●● Secondary PCB hole
Remarks
Ø 1.5 mm
Ø 0.7 mm
●● VOUT is positive when IP flows from terminals 1, 7 (IN) to
terminals 2, 8 (OUT).
●● Temperature of the primary conductor should not exceed
100°C.
Page 3/3
120416/14
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
很抱歉,暂时无法提供与“HXS 10-NP/SP3”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+88.99666
- 6+84.54995
- 12+83.68560